home oil & gas division IT division contact us sitemap

About Us
Services
Pipeline Field Joint Infill &
Coating
Past Projects
Vacancy
Contact Us
 


Oil & Gas Division

>>> Pipeline Field Joint Infill & Coating Services (4/4)



Advantages of HDPU Foam Against Mastic

HDPUF have been used for pipeline installation since the early 1980’s and have proven to be advantageous in the following areas:
  • Non hazardous – the chemicals and final product do not emit toxic fumes when dispensed and provides a safe environment for personnel in the field joint station.
  • Handling – The chemicals expand approximately 6 times the actual volume. Therefore, 6 times less materials to handle, store and transport.
  • Easy Application – Dispensing the chemicals do not require high temperature and therefore eliminate the hazard of burns to the personnel.
  • Chemicals ready to be used immediately, does not need high labor to prepare.
Other Related Products

In addition to the provision of HDPUF application services, OAG is able to provide the following product for pipeline field joint application:

  • Cold Applied Anti Corrosion Tape Wrap – BITUTAPE 165PVC
  • BITUTAPE 165PVC is a cold applied anti corrosion tape wrap that has been proven as an effective an anti corrosion coating for pipeline field joints.
  • BITUTAPE 165PVC can be applied to suit the requirement of the designers i.e. by spiral wrap or cigarette wrap methods

The specification of BITUTAPE 165PVC is as follows:

Properties Test Standard Unit Value
Backing Color - - Black / Blue
Backing Type - - PVC
Backing Thickness ASTM D 1000 Microns 750
Total Thickness ASTM D 1000 mm 1.65
Tensile Strength ASTM D 638 N/mm² 28.7
Elongation BS 2782 % 290
Tape Strength ASTM D 1000 N/mm >12
Tear Resistance ASTM D 1004 N >75
Adhesion to Primed Steel ASTM D 1000 N/mm 5
Adhesion to Self ASTM D 1000 N/mm 8
Impact Resistance DIN 30672 N.M 25
Di Electric Strength BS 2782 Kv >40
Insulation Resistance ASTM D 257 Ohms 9.8x10¹³
Cathodic Disbondment Resistance ASTM G 8 mm <10
Water Vapor Transmission ASTM E 90 gms/m²/24 hrs 0.88
Water Absorption ASTM D 570 % 0.01
Resistance to Bacteria Attack ASTM G21 - Excellent
Application Temperature   Degree Celcius +5 to +50
Service Temperature   Degree Celcius  -20 to +100


 


 

 
 